AG501 – Now available as a basic model

Aside

Herewith we would like to present the first extension of our product range of the current AG501, the AG501-ip (in parts).

The AG501-ip works with all functions and programs of the AG501.
Like the original AG501, our 9 frequencies are transmitting continuously (no settling time).
The data are transmitted with 1 MHz, the position data are provided with 1250Hz.

With the basic model the data can be collected and evaluated in the same way. Due to the absence of the calibration device, there is only a minimal difference in accuracy. Instead of the usual accuracy of 0.3mm RMS, the basic model (without calibration device) has an accuracy of 0.6mm RMS.

The AG501-ip consists exclusively of original AG501 parts. Thus the basic model can be extended to the original AG501 at any time.
The possible combinations are listed below

  • AG501-ip (basic model):
    • Transmitterholder with 9 transmitting coils
    • Sybox (Synchronization box)
    • E-Box (electronics including FPGA board)
    • Sensin, for 8 channels (receive amplifier)
    • 8 sensors (small size, high flexible, Nosofree® antimicrobial cable)
    • Programs for control and position determination
  • AG501-ip (basic model +):
    • Stand with height adjustment
      or
    • Stand with height adjustment and calibration unit
      (corresponds to the original AG501)

 

Catalogue with prices on request

7th International Conference on SMC in Groningen, Netherlands

July 5 – 8, 2017: the 7th International Conference on Speech Motor Control
Groningen, the Netherlands
Website: http://www.slp-nijmegen.nl/smc2017/
Carstens Medizinelektronik will present The Dual arrangement of the Articulograph AG501 during an EMA workshop on Friday 7th July from 18:00 to 19:15.(Workshop features in pdf)

The final agenda in pdf : https://www.articulograph.de/wp-content/uploads/2017/06/Agenda-Workshop-smc2017.pdf

We are looking forward to meeting you there

Online Meeting on the 17th February 2017

We are delighted to inform you that a new Online meeting on the „Post Processing of AG501 Data“  will take place on the 17th February  2017.
During this seminar the following points will be discussed;

  •  Performing the Head Correction (using reference Sensors) and the Head alignment  (using the Bite Plane)
  •  Using the real time display with contours.

for more information about the Meeting and how to join the meeting please read the following Pdf file.

The Answers of the past meeting in the pdf file.